a0   actually   amber   and   appears   as   As   awry   bay   be   become   before   blink   blinking   both   but   by   can   Check   choice   deity   deleuze   Dell   do   documentation   Drive   drive   drives   Ds   Each   Failed   failed   follow   for   four   green   had   has   have   If   in   Info   Install   install   instructions   into   is   ld   Locate   logical   lower   maintenance   manual   may   megarc   monitored   must   new   no   normal   not   number   of   old   on   operation   or   pair   per   Physical   potentially   pray   prepared   Rbld   rebuild   removal   Remove   removed   removing   Replacement   Replacing   report   root   run   running   safe   safely   says   screw   second   should   show   sled   something   Status   steady   still   straightforward   Target   that   The   the   then   there   This   this   three   times   to   top   unscrew   way   We   where   whole   will   your  

Clear message
Edit

DeleuzeHotSwapDrive

1. Replacing Failed Drive on deleuze

1.1. Locate Failed Drive

Each drive bay has a pair of LEDs; drives in normal operation will both be green (top potentially blinking). A failed drive's lower LED will be blinking amber four times per second.

1.2. Remove Failed Drive

The Dell documentation says the drive must be prepared for removal, but there appears to be no way to do this. We have safely removed a drive blinking amber before; follow the Dell maintenance manual instructions for removing the drive and pray to a deity of your choice that this is actually safe.

1.3. Install Replacement Drive

This should be straightforward -- unscrew the old drive and screw the new drive into the sled, and install.

The lower LED on the sled may blink amber for a second or three and then should become steady green. If not something is awry.

1.4. Check RAID Status

As root on deleuze run (where N = logical drive number that had a failed drive):

megarc -ldInfo -a0 -LN

This should report the Physical Target Status of the new drive as RBLD and the logical drive as a whole should still be DEGRADED. The rebuild can be monitored by running:

megarc -showRbld -a0